Hirashima, T. and Uesugi, H., 2005. Load-bearing Capacity Of H-shaped Steel Columns Under Local Buckling At Elevated Temperature. Fire Safety Science 8: 211-222. doi:10.3801/IAFSS.FSS.8-211
ABSTRACT
When a compartment fire occurs in a building of steel structure, large bending deformations are produced at the ends of columns and beams, inducing local buckling at these points. In this study, the load-bearing capacity of H-shaped steel columns under local buckling is clarified from pure compression tests and bending compression tests at constant temperatures ranging from room temperature to 600°C. On the basis of the tests, we propose, in relation to the fire resistance of H-shape steel stub columns, a relation between safety usable steel temperature and constant axial load ratio.
Keyword(s):
fire resistance, h-shaped steel member, stub column, local buckling, pure compression test, bending compression test