$site = "publications.iafss.org"; $fullsite = "publications.iafss.org"; $basePath = "/home2/firesag5/private/data/"; ?>
Keough, J.J., 1986. Translation Of Research Into Practice. Fire Safety Science 1: 593-601. doi:10.3801/IAFSS.FSS.1-593
View Abstract | View Article
Nakamura, H., 1986. Investment Model Of Fire Protection Equipment For Office Building. Fire Safety Science 1: 1019-1028. doi:10.3801/IAFSS.FSS.1-1019
View Abstract | View Article
Yu, H.Z., 1986. Investigation Of Spray Patterns Of Selected Sprinklers With The Fmrc Drop Size Measuring System. Fire Safety Science 1: 1165-1176. doi:10.3801/IAFSS.FSS.1-1165
View Abstract | View Article
Lee, J.L., 1986. Extinguishment Of Rack Storage Fires Of Corrugated Cartons Using Water. Fire Safety Science 1: 1177-1186. doi:10.3801/IAFSS.FSS.1-1177
View Abstract | View Article
Unoki, J., 1986. Fire Extinguishing Time By Sprinkler. Fire Safety Science 1: 1187-1196. doi:10.3801/IAFSS.FSS.1-1187
View Abstract | View Article
Pietrzak, L.M. and Johanson, G.A., 1986. Analysis Of Fire Suppression Effectiveness Using A Physically Based Computer Simulation. Fire Safety Science 1: 1207-1216. doi:10.3801/IAFSS.FSS.1-1207
View Abstract | View Article
Heskestad, G. and Bill, R.G., 1989. Modeling Of Thermal Responsiveness Of Automatic Sprinklers. Fire Safety Science 2: 603-612. doi:10.3801/IAFSS.FSS.2-603
View Abstract | View Article
Sako, S. and Hasemi, Y., 1989. Response Time Of Automatic Sprinklers Below A Confined Ceiling. Fire Safety Science 2: 613-622. doi:10.3801/IAFSS.FSS.2-613
View Abstract | View Article
Cooper, L.Y. and Stroup, D.W., 1989. Test Results And Predictions For The Repsonse Of Near-ceiling Sprinkler Links In A Full-scale Compartment Fire. Fire Safety Science 2: 623-632. doi:10.3801/IAFSS.FSS.2-623
View Abstract | View Article
Kung, H.C., Yu, H.Z., Brown, W.R. and Vincent, B.G., 1989. Four-tier Array Rack Storage Fire Tests With Fast-response Prototype Sprinklers. Fire Safety Science 2: 633-642. doi:10.3801/IAFSS.FSS.2-633
View Abstract | View Article
Bill, R.G., Kung, H.C., Brown, W.R. and Hill, E.E., 1989. Effects Of Cathedral And Beamed Ceiling Construction On Residential Sprinkler Performance. Fire Safety Science 2: 643-653. doi:10.3801/IAFSS.FSS.2-643
View Abstract | View Article
Yu, H.Z., Kung, H.C. and Han, Z., 1989. The Effects Of Spray Cooling On The Ceiling Gas Temperature At The Door Opening Of Room Fires. Fire Safety Science 2: 655-665. doi:10.3801/IAFSS.FSS.2-655
View Abstract | View Article
Kung, H.C., Spaulding, R.D. and Stavrianidis, P., 1991. Fire Induced Flow Under A Sloped Ceiling. Fire Safety Science 3: 271-280. doi:10.3801/IAFSS.FSS.3-271
View Abstract | View Article
Beever, P., 1991. Cabins And Islands: A Fire Protection Strategy For An International Airport Terminal Building. Fire Safety Science 3: 709-718. doi:10.3801/IAFSS.FSS.3-709
View Abstract | View Article
Di Marzo, M., Liao, Y., Tartarini, P., Evans, D.D. and Baum, H.R., 1991. Dropwise Evaporative Cooling Of A Low Thermal Conductivity Solid. Fire Safety Science 3: 987-996. doi:10.3801/IAFSS.FSS.3-987
View Abstract | View Article
Wighus, R., 1991. Extinguishment Of Enclosed Gas Fires With Water Spray. Fire Safety Science 3: 997-1006. doi:10.3801/IAFSS.FSS.3-997
View Abstract | View Article
White, G., Tinker, S. and Dimarzo, M., 1994. Modelling Of Dropwise Evaporative Cooling On A Semi-infinite Solid Subjected To Radiant Heat Input. Fire Safety Science 4: 217-228. doi:10.3801/IAFSS.FSS.4-217
View Abstract | View Article
Chan, T.S., Kung, H.C., Yu, H.Z. and Brown, W.R., 1994. Experimental Study Of Actual Delivered Density For Rack-storage Fires. Fire Safety Science 4: 913-924. doi:10.3801/IAFSS.FSS.4-913
View Abstract | View Article
Alvares, N.J., Hasegawa, H.K., Hout, K,, Fernandez-Pello, A.C. and White, J., 1994. Analysis Of A Run-away High Rack Storage Fire. Fire Safety Science 4: 1267-1278. doi:10.3801/IAFSS.FSS.4-1267
View Abstract | View Article
Yao, C., 1997. Overview Of Sprinkler Technology Research. Fire Safety Science 5: 93-110. doi:10.3801/IAFSS.FSS.5-93
View Abstract | View Article
Bill, R.G. and Heskestad, G., 1997. Thermal Sensitivity Evaluation Of Recessed, Flush And Concealed Sprinklers. Fire Safety Science 5: 865-876. doi:10.3801/IAFSS.FSS.5-865
View Abstract | View Article
Kung, H.C., Vincent, B.G., Chan, T.S., Yu, H.Z. and Stavrianidis, P., 1997. Early Suppression Fast Response(esfr) Sprinkler Protection For 12m High Warehouses. Fire Safety Science 5: 877-888. doi:10.3801/IAFSS.FSS.5-877
View Abstract | View Article
Kumar, S., Heywood, G.M. and Liew, S.K., 1997. Superdrop Modelling Of A Sprinkler Spray In A Two-phase Cfdparticle Tracking Model. Fire Safety Science 5: 889-900. doi:10.3801/IAFSS.FSS.5-889
View Abstract | View Article
Novozhilov, V., 2000. Computational Fluid Dynamics Predictions Of Thermoplastic Fire Suppression By Water Spray. Fire Safety Science 6: 387-398. doi:10.3801/IAFSS.FSS.6-387
View Abstract | View Article
Nyankina, K. and Turan, O.F., 2000. Optimal Droplet Diameter And Relative Sprinkler Location In Fire- Sprinkler Lnteraction. Fire Safety Science 6: 421-432. doi:10.3801/IAFSS.FSS.6-421
View Abstract | View Article
Holborn, P.G., Nolan, P.F. and Kumar, S., 2000. A 'meandrop' Method For The Characterisation Of A Sprinkler Spray In A Two-phase Cfd-particle Tracking Model - An Improved Alternative To The 'superdrop' Method.. Fire Safety Science 6: 433-444. doi:10.3801/IAFSS.FSS.6-433
View Abstract | View Article
Mcgrattan, K.B., Hamins, A. and Forney, G.P., 2000. Modeling Of Sprinkler, Vent And Draft Curtain Lnteraction. Fire Safety Science 6: 505-516. doi:10.3801/IAFSS.FSS.6-505
View Abstract | View Article
Mcgrattan, K.B. and Sheppard, D., 2000. Sprinkler, Vent, Draft Curtain Lnteraction - Experiments. Fire Safety Science 6: 517-528. doi:10.3801/IAFSS.FSS.6-517
View Abstract | View Article
Chan, T.S. and Yu, H.Z., 2000. The Effect Of In-Duct Sprinkler Operation On Exhaust Of Fire Gases From Clean Room Wet Benches. Fire Safety Science 6: 1149-1160. doi:10.3801/IAFSS.FSS.6-1149
View Abstract | View Article
Chan, T.S. and Kung, H.C., 2003. Comparison Of Actual Delivered Density And Fire Suppression Effectiveness Of Standard And Conventional Sprinklers In Rack-storage Fires. Fire Safety Science 7: 445-456. doi:10.3801/IAFSS.FSS.7-445
View Abstract | View Article
Hamins, A. and Mcgrattan, K.B., 2003. Reduced-scale Experiments On The Water Suppression Of A Rack-storage Commodity Fire For Calibration Of A Cfd Fire Model. Fire Safety Science 7: 457-468. doi:10.3801/IAFSS.FSS.7-457
View Abstract | View Article
Ruffino, P. and Dimarzo, M., 2003. The Effect Of Evaporative Cooling On The Activation Time Of Fire Sprinklers. Fire Safety Science 7: 481-492. doi:10.3801/IAFSS.FSS.7-481
View Abstract | View Article
Nam, S., Braga, A., Kung, H.C. and Troup, J., 2003. Fire Protection For Non-storage Occupancies With High Ceiling Clearances. Fire Safety Science 7: 493-504. doi:10.3801/IAFSS.FSS.7-493
View Abstract | View Article
Frangi, A. and Fontana, M., 2005. Fire Performance Of Timber Structures Under Natural Fire Conditions. Fire Safety Science 8: 279-290. doi:10.3801/IAFSS.FSS.8-279
View Abstract | View Article
Zhuiykov, S. and Dowling, V.P., 2005. Maintenance Testing Of Sprinkler Heads: Qualitative Analysis Causes Of Failures. Fire Safety Science 8: 811-822. doi:10.3801/IAFSS.FSS.8-811
View Abstract | View Article
Schwille, J.A., Kung, H.C., Hjohlman, M., Laverick, G.E. and Gardell, G.W., 2005. Actual Delivered Density Fire Test Apparatus For Sprinklers Protecting High Commodity Storage. Fire Safety Science 8: 823-833. doi:10.3801/IAFSS.FSS.8-823
View Abstract | View Article
Xin, Y. and Meredith K., 2014. Characterization of Fire Suppression of an Idealized Commodity Using Uniform Water Fluxes. Fire Safety Science 11: 1208-1221. 10.3801/IAFSS.FSS.11-1208
View Abstract | View Article
Wang, Y., Meredith K., Zhou, X., Chatterjee, P., Xin, Y., Chaos M., Ren, N. and Dorofeev, S., 2014. Numerical Simulation of Sprinkler Suppression of Rack Storage Fires. Fire Safety Science 11: 1170-1183. 10.3801/IAFSS.FSS.11-1170
View Abstract | View Article
Member's Page | Join IAFSS | Author's Site
Copyright © International Association for Fire Safety Science